Ensure power leads and water hoses are correctly and securely connected.
Place tub under discharge chute.
Press start button on control panel to run mixer before opening manual butterfly valve.
Open butterfly valve to allow material into dry chamber, which will then be fed into the wet chamber where water addition takes place.
Adjust workability of mortar, as required, by using the water flow control valve.
When the amount of mortar being discharged into the tub is nearing the required amount, close the butterfly valve and keep the mixer running. The remaining mortar inside the unit will then be discharged into the tub. When all of the mortar has run out of the discharge point and only water is left running from it, you will know that the mixer is clean and you can press the stop button.
Using the Timer
It is possible to run the silo mixer unit via the timer on the control panel.
Simply set the desired running time and press the start button. The mixer will stop automatically when the set time has expired.
Please note the following when the timer method is utilised:
If the mixer is left for over an hour after it was last used, the mortar left in the wet chamber will start to set, especially in hot weather. This will overload the mixer motor next time it is used and could result in damage to the motor and its eventual failure. To avoid this, ensure that the butterfly valve is closed and press the start button to run the residue out of the mixer chamber before the material has time to gain an initial set. When only water starts to run out of the discharge point, this means the mixer is clean.
Silo Control Panel
See below for an illustration of the control panel:
Helpful Hints
In addition to observing the cleaning procedure and to ensure trouble-free usage of the dry silo system, here are some more helpful hints.
The butterfly valve must be closed when a refill is being discharged into an empty silo, otherwise material will blow straight into the mixer unit, meaning the motor will be under duress when started.
In winter months, freezing water may seriously damage the control panel and the water fittings. In cases of long intervals between use and at the end of the working day, please ensure that the water fittings are completely drained as follows:
Turn off the water supply
Uncouple the water supply pipe
Uncouple the pipe from the mixer unit
Open water drain taps
Put switch into the brush position
Let water drain off accordingly.
In areas where site security is an issue, it is advisable to remove the control panel from the silo, by disconnecting the water pipes and electrical leads, before lifting it off the bracket and placing it in a secure location to prevent damage by vandalism or theft.
Take care of the equipment that Remix provide to your site. Any damage to instrumentation or switches on the mixer/control panel could interfere with the normal operation of the silo system, resulting in unnecessary downtime and loss of productivity for your site. Ensure that site vehicles, used for loading and transporting mortar, avoid contact with the silo and its equipment at all times.
Once a week, it is advised that you inspect the silo mixing chamber. The procedure will be demonstrated by the Remix engineer at the initial training session. If there is any build-up on the screw or on the inside of the chamber, please remove it with a wire brush. Contact Remix if any wearing parts (e.g. scrapers) need renewing. The engineer will attend your site to replace any worn parts and will conduct a mixer/control panel service.
This website uses cookies to improve your experience. We'll assume you're ok with this, but you can opt-out if you wish.AcceptRead More
Privacy & Cookies Policy
Privacy Overview
This website uses cookies to improve your experience while you navigate through the website. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. We also use third-party cookies that help us analyze and understand how you use this website. These cookies will be stored in your browser only with your consent. You also have the option to opt-out of these cookies. But opting out of some of these cookies may affect your browsing experience.
Necessary cookies are absolutely essential for the website to function properly. This category only includes cookies that ensures basic functionalities and security features of the website. These cookies do not store any personal information.
Any cookies that may not be particularly necessary for the website to function and is used specifically to collect user personal data via analytics, ads, other embedded contents are termed as non-necessary cookies. It is mandatory to procure user consent prior to running these cookies on your website.